Key Benefits:  

  • Class II Electrically Insulated Coating
  • Designed to Network Rail Class II Specification NR/L2/SIGELP/27409
  • Tested to IP4X/IP44 and Impact Resistance to IK10
  • Designed for 40 year life
  • Compatible with both Aluminium and Copper cables
  • Most models are fitted with removable or sliding gland plates to aid main cable installation
  • Small footprint for Legacy retrofit use
  • Mount on standard BRS-SM 440 rails or wooden backboard
  • Compatible with existing Legacy and Ring Circuit power supply arrangements
  • Every enclosure factory tested to verify 3KV coating dielectric strength
  • Surge Arrestor (switched/fused) option
  • Provides safe isolation (pad lockable OFF)
  • Includes isolation and fuse protection of functional output supplies

 

Available Models:

SafeBox Compact C32

  • Class II Distribution Unit (690V rated).
  • Power IN/OUT with 3 functional output supplies.
  • Fuse carriers: IEC 60269 (10 x 38mm).
  • (Cu) or (Al) Feeder Cables 6 to 120mm².
  • Ring Circuit (FSP01/02).
  • Removable gland plate.
  • Gland plate to terminal distance: 180mm

The above model is also available with:
  -  1 Functional output supply (SafeBox C11 - CAT:  091/019324).
  -  2 Functional output supplies (SafeBox C22 - CAT: 091/019325).

 

  CAT No. 091/019320

 

 SafeBox Compact C32/SA

  • Class II Distribution Unit (690V rated).
  • Power IN/OUT with 2 functional output supplies.
  • Approved internal Surge Arrestor (switched/fused).
  • Fuse carriers: IEC 60269 (10 x 38mm).
  • (Cu) or (Al) Feeder Cables 6 to 120mm².
  • Ring Circuit (FSP01/02).
  • Removable gland plate.
  • Gland plate to terminal distance: 180mm

The above model is also available with:
-  1 Functional output supply (SafeBox C22/SA - CAT: 091/019319).

 

 CAT No. 091/019321

 

SafeBox SIN119/1SW50

  • Small footprint for legacy retrofit use.
  • Class II Distribution Unit (690V rated).
  • Power IN/OUT (Tunnel type terminals).
  • 1 functional output supply.
  • Fuse carriers: IEC 60269 (10 x 38mm).
  • Feeder Cables 2.5(Cu)/6.0(Al) to 50mm².
  • Legacy Circuit (FSP04).
  • Sliding gland plate.
  • Gland plate to terminal distance: 126mm

 

CAT No. 0091/001915

 

 SafeBox SIN119/2SW50

  •  Small footprint for legacy retrofit use.
  • Class II Distribution Unit (690V rated).
  • Power IN/OUT (Tunnel type terminals).
  • 2 functional output supplies.
  • Fuse carriers: IEC 60269 (10 x 38mm).
  • Feeder Cables 2.5(Cu)/6.0(Al) to 50mm².
  • Legacy Circuit (FSP04).
  • Sliding gland plate.
  • Gland plate to terminal distance: 196mm

 

 CAT No. 0091/001916

 SafeBox SIN119/1SW50R

  •  Small footprint for legacy retrofit use.
  • Class II Distribution Unit (690V rated).
  • Power IN/OUT (Tunnel type terminals).
  • 1 functional output supply.
  • Fuse carriers: IEC 60269 (10 x 38mm).
  • Feeder Cables 2.5(Cu)/6.0(Al) to 50mm².
  • Ring Circuit (FSP02).
  • Sliding gland plate.
  • Gland plate to terminal distance: 196mm

 

 CAT No. 0091/001917

 SafeBox SIN119/1SW95

  •  Small footprint for legacy retrofit use.
  • Class II Distribution Unit (690V rated).
  • Power IN/OUT (Tunnel type terminals).
  • 1 functional output supply.
  • Fuse carriers: IEC 60269 (10 x 38mm).
  • Feeder Cables (Cu) or (Al) 16 to 95mm².
  • Legacy Circuit (FSP04).
  • Sliding gland plate.
  • Gland plate to terminal distance: 126mm

 

  CAT No. 0091/001918

 SafeBox SIN119/2SW95

  •  Small footprint for legacy retrofit use.
  • Class II Distribution Unit (690V rated).
  • Power IN/OUT (Tunnel type terminals).
  • 2 functional output supplies.
  • Fuse carriers: IEC 60269 (10 x 38mm).
  • Feeder Cables (Cu) or (Al) 16 to 95mm².
  • Legacy Circuit (FSP04).
  • Sliding gland plate.
  • Gland plate to terminal distance: 196mm

 

 CAT No. 0091/001919

  SafeBox SIN119/1SW95R

  •  Small footprint for legacy retrofit use.
  • Class II Distribution Unit (690V rated).
  • Power IN/OUT (Tunnel type terminals).
  • 1 functional output supply.
  • Fuse carriers: IEC 60269 (10 x 38mm).
  • Feeder Cables (Cu) or (Al) 16 to 95mm².
  • Ring Circuit (FSP02).
  • Sliding gland plate.
  • Gland plate to terminal distance: 196mm

 

 CAT No. 0091/001920

 SafeBox SIN119/1SW120

  •  Small footprint for legacy retrofit use.
  • Class II Distribution Unit (690V rated).
  • Power IN/OUT (Tunnel type terminals).
  • 1 functional output supply.
  • Fuse carriers: IEC 60269 (10 x 38mm).
  • Feeder Cables (Cu) or (Al) 35 to 120mm².
  • Legacy Circuit (FSP04).
  • Sliding gland plate.
  • Gland plate to terminal distance: 153mm

 

 CAT No. 0091/001921

 SafeBox SIN119/2SW120

  •  Small footprint for legacy retrofit use.
  • Class II Distribution Unit (690V rated).
  • Power IN/OUT (Tunnel type terminals).
  • 2 functional output supplies.
  • Fuse carriers: IEC 60269 (10 x 38mm).
  • Feeder Cables (Cu) or (Al) 35 to 120mm².
  • Legacy Circuit (FSP04).
  • Sliding gland plate.
  • Gland plate to terminal distance: 186mm

 

 CAT No. 0091/001922
 SafeBox SIN119/1SW120R

  •  Small footprint for legacy retrofit use.
  • Class II Distribution Unit (690V rated).
  • Power IN/OUT (Tunnel type terminals).
  • 1 functional output supply.
  • Fuse carriers: IEC 60269 (10 x 38mm).
  • Feeder Cables (Cu) or (Al) 35 to 120mm².
  • Ring Circuit (FSP02).
  • Sliding gland plate.
  • Gland plate to terminal distance: 186mm

 

 CAT No. 0091/001923

 SafeBox Mini 21

  •  Smallest footprint for legacy retrofit use.
  • Class II Distribution Unit (690V rated).
  • Power IN/OUT with 1 functional output supply.
  • Fuse carriers: IEC 60269 (10 x 38mm).
  • (Cu) or (Al) Feeder Cables up to 50mm².
  • Ring Circuit (FSP01/02).
  • Gland holes to terminal distance: 70mm

 

 PA05/06439

 

 

 

 

Please click the link below to view the SIN119 O&M manual:

 SafeBox SIN119 Range Class II O&M Manual Ver 1.0

 

 
   
   
   

 

PADS numbers covering the range: 091/019319, 091/019320, 091/019321, 091/019322, 091/019323, 091/019324, 091/019325, 091/019326, 091/019327, 0091/001915, 0091/001916, 0091/001917, 0091/001918, 0091/001919, 0091/001920, 0091/001921, 0091/001922, 0091/001923

Henry Williams Limited

Dodsworth Street
Darlington
County Durham
DL1 2NJ

Email: Please use form opposite.
Tel: 01325 462722
Fax: 01325 245220

To view our location click here

About Henry Williams

The story of Henry Williams Limited goes back to 1883, when the company was formed to manufacture control and signalling equipment for the rapidly expanding railways network. Since those historic and pioneering days, our skills have broadened, our technology has advanced with the time and our sphere of influence has widened considerably....read more

This website uses cookies
We use cookies to personalise content, to provide social media features and to analyse our traffic. We also share information about your use of our site with our social media and analytics partners who may combine it with other information that you’ve provided to them or that they’ve collected from your use of their services.
If you want to know more about the cookies in use on this website before choosing please read our Privacy Policy.